Olá, Weverton. Podem considerar encerrado o andamento deste artigo no Serviço de Editoração Científica (SEC) da Biblioteca Central da UFG. Atenciosamente, Thiago
DOI:
https://doi.org/10.1590/1809-6891v26e-80607EAbstract
This study was conducted to evaluate the viability of porcine corneal endothelium after conditioning in the preservation medium Eusol-C. Twelve eyes from six 6-month-old male Large White pigs (Sus scrofa domesticus) were analyzed. Endothelial cell morphology and cell count of all samples were assessed prior storage using specular microscopy to ensure that only healthy corneas were included in the study. The samples were randomly divided into a control group (G1) and a test group (G2). Corneas from G1 were immediately submerged in bottles containing 2.5% glutaraldehyde, whereas corneas from G2 were stored in Eusol-C at 4°C for 14 days. The percentage of endothelial cell loss was evaluated using scanning electron microscopy (SEM). Comparisons between regions were performed using repeated measures Analysis of Variance (ANOVA). Differences were considered statistically significant at P < 0.05. Corneal samples from G1 showed no areas of endothelial cell loss. In samples from G2, the average cell loss was 3.01%. In conclusion, the hypothermic medium Eusol-C satisfactorily preserved porcine corneas for up to 14 days.
Downloads
References
Joyce NC. 2012. Capacidade proliferativa das células endoteliais corneanas. Exp Eye Res 95: 16-23. Available from: https://doi.org/10.1016/j.exer.2011.08.014
Lee SE, Mehra R, Fujita M, Roh DS, Long C, Lee W, Funderburgh JL, Ayares DL, Cooper DKC, Hara H. 2013. Caracterização do endotélio corneano de porco para xenotransplante. Semin Ophthalmol 29: 127-135. Available from: https://doi.org/10.3109/08820538.2013.787104
Yoeruek E, Bayyoud T, Maurus C, Hofmann J, Spitzer MS, Schmidt KUB, Szurman P. 2012. Reconstrução do estroma corneano com xenógenos de córnea porcina decelularizada em um modelo de coelho. Acta Ophthalmol 90: 206-210. Available from: https://doi.org/10.1111/j.1755-3768.2011.02300.x
Isidan A, Liu S, Li P, Lashmet M, Smith LJ, Hara H. 2019. Métodos de decelularização para o desenvolvimento de xenotransplantes de córnea porcina e perspectivas futuras. Xenotransplantation 26: e12564. Available from: https://doi.org/10.1111/xen.12564
Yoon CH, Choi HJ, Kim MK. 2021. Xenotransplante de córnea: Qual é o nosso estágio atual? Prog Ret Eye Res 80: 1-40. Available from: https://doi.org/10.1016/j.preteyeres.2020.100876
Saad HA, Terry MA, Shamie N, Chen ES, Friend DF, Holiman JD, Stoeger C. 2008. Um método simples e barato para análise quantitativa de dano endotelial utilizando coloração vital e software Adobe Photoshop. Cornea 27: 818-824. Available from: https://doi.org/10.1097/ICO.0b013e3181705ca2
Menduni F, Davies LN, Madrid-Costa D, Fratini A, Wolffsohn JS. 2018. Caracterização do globo ocular suíno como modelo in vitro para síndrome do olho seco. Cont Lens Anterior Eye 41: 13-17. Available from: https://doi.org/10.1016/j.clae.2017.09.003
Crespo-Moral M, García-Posadas L, López-Garcia A, Diebold Y. 2020. Caracterização histológica e imuno-histoquímica da superfície ocular de suínos. PLoS One 15: 1-17. Available from: https://doi.org/10.1371/journal.pone.0227732
Ellis MF, McGhee CNJ, Lee WR. 1992. Estudo do endotélio corneano suíno armazenado em sulfato de condroitina por microscopia eletrônica de varredura. Cornea 11: 127-132. Available from: https://doi.org/10.1097/00003226-199203000-00006
Rodella U, Bosio L, Ferrari S, Gatto C, Giurgola L, Rossi O, Ciciliot S, Ragazzi E, Ponzin D, Tothova JD. 2023. Modelo de armazenamento ex vivo de córnea suína como alternativa ao tecido de doadores humanos para investigações sobre preservação da camada endotelial. Transl Vis Sci Technol 12: 1-13. Available from: https://doi.org/10.1167/tvst.12.4.24
Giurgola L, Rodella U, Gatto C, Rossi O, Honisch C, Ragazzi E, Ruzza P, Ferrari S, Tothova JD. 2024. Avaliação de desempenho e segurança do armazenamento hipotérmico em câmara corneana e lavagem corneana com PSS-L em córneas humanas e suínas. BMJ Open Ophthalmol 9: e001453. Available from: https://doi.org/10.1136/bmjophth-2023-001453
Albuquerque L, Pigatto AM, Pigatto JAT. 2020. Avaliação do endotélio corneano equino (Equus caballus) armazenado no meio de preservação Eusol-C®. Semina: Cienc Agrar 41: 3155-3164. Available from: https://doi.org/10.5433/1679-0359.2020v41n6Supl2p3155
Arndt C, Reese S, Köstlin R. 2001. Preservação de tecido corneoescleral de cães e gatos em Optisol® GS. Vet Ophthalmol 4: 175-182. Available from: https://doi.org/10.1046/j.1463-5216.2001.00146.x
Kim SY, Park YH, Lee YC. 2008. Comparação do efeito da moxifloxacina, levofloxacina e cefazolina intracamerais sobre células endoteliais da córnea de coelhos. Clin Exp Ophthalmol 36: 367-370. Available from: https://doi.org/10.1111/j.1442-9071.2008.01771.x
Kunzmann BC, Hellwinkell OJC, Klameth C, Wenzel D, Bartz-Schmidt KU, Spitzer MS, Schultheiss M. 2017. Estabelecimento de um modelo de cultura organotípica do endotélio corneano suíno para fins de pesquisa. Cell Tissue Banking 19: 269-276. Available from: https://doi.org/10.1007/s10561-017-9669-7
Liou SW, Chiu CJ, Wang IJ. 2004. Efeito da injeção intracameral de lidocaína e carbacol sobre o endotélio corneano de coelhos. J Cataract Refract Surg 30: 1351-1355. Available from: https://doi.org/10.1016/j.jcrs.2003.10.032
Pigatto JAT, Abib FC, Pizzeti JC, Laus JL, Santos JM, Barros PSM. 2005. Análise morfométrica do endotélio corneano de coelhos por microscopia eletrônica de varredura. Acta Sci Vet 33: 41-45. Available from: http://hdl.handle.net/10183/20027
Tamayo-Aranjo LJ, Baraldi-Artoni SN, Laus JL, Vicenti FAM, Pigatto JAT, Abib FC. 2009. Morfologia ultraestrutural e morfometria do endotélio corneano normal de suínos mestiços adultos. Cienc Rural 39: 117-122. Available from: https://doi.org/10.1590/S0103-84782009000100018
Fujita M, Mehra M, Lee SE, Roh DS, Long C, Fundenburgh JL, Ayares DL, Cooper DKC, Hara H. 2013. Comparação da capacidade proliferativa de células endoteliais corneanas geneticamente modificadas de suínos e humanos. Ophthalmic Res 49: 127-138. Available from: https://doi.org/10.1159/000342978
Brooks DE, Plummer CE, Kallberg ME, Barrie KP, Ollivier FJ, Hendrix DVH, Baker A, Scotty NC, Utter ME, Blackwood SE, Nunnery CM, Ben-Sholmo G, Gelatt KN. 2008. Transplante de córnea para ceratopatias inflamatórias em equinos: Resultado visual em 206 casos (1993–2007). Vet Ophthalmol 11: 123-133. Available from: https://doi.org/10.1111/j.1463-5224.2008.00611.x
Henriksen ML, Plummer CE, Mangan B, Ben-Sholmo G, Tsujita H, Greenberg S, Toft N, Brooks DE. 2012. Resultado visual após transplante de córnea por perfuração corneana e prolapso de íris em 37 cavalos: 1998–2010. Equine Vet J 44: 115-119. Available from: https://doi.org/10.1111/j.2042-3306.2012.00657.x
Usha B, Kontsevaya S, Lutsay V, Nityaga IM, Lukashina UE. 2019. Ceratoplastia penetrante com córnea de doador preservada na oftalmologia veterinária. J Mol Biol Res 9: 71. Available from: http://dx.doi.org/10.5539/jmbr.v9n1p71
Kanavi MR, Javadi MA, Chamani T, Fahim P, Javadi F. 2014. Comparação dos índices quantitativos e qualitativos de córneas doadas mantidas em Optisol-GS com aquelas mantidas em Eusol-C. Cell Tissue Bank 16: 243-247. Available from: https://doi.org/10.1007/s10561-014-9466-5
Yuksel MB, Uzunel UD, Küsbeci T. 2016. Viabilidade de células endoteliais de córneas doadoras preservadas no meio de armazenamento corneano Eusol-C. Exp Clin Transplant 14: 441-444. Available from: https://doi.org/10.6002/ect.2014.0295
Rodella U, Piaia M, Giurgola L, Gatto C, Tóthová JD. 2025. Modelo ex vivo de córnea e globo ocular bovino para simular condições de armazenamento de córnea humana e cirurgias oculares. Cell Tissue Bank 26: 1-13. Available from: https://doi.org/10.1007/s10561-025-10162-7
Wang Q, Liu Y, Gao Y, Zhang M, Yang L, Hu J, Ren Y, Zhou Q, Zhu M. 2024. Comparação da integridade estrutural e qualidade do endotélio corneano armazenado em meio de cultura de órgão versus Eusol-C. Cell Tissue Bank 25: 839-850. Available from: https://doi.org/10.1007/s10561-024-10138-z
Gisoldi RAMC, Pocobelli G, Rodella U, Giurgola L, Gatto C, Lodato G, Buffon G, Nucci C, Tóthová JD, Pocobelli A. 2024. Resultados clínicos retrospectivos de ceratoplastia utilizando córneas humanas doadoras preservadas em meio de armazenamento hipotérmico Eusol-C. J Clin Med 13: 1-13. Available from: https://doi.org/10.3390/jcm13247606
Mena-Linares EE, Vásquez-Maya L, García-Carmona K, Martínez-Mijared MA, Baldivieso-Hurtado R. 2023. Viabilidade de células endoteliais comparando Eusol-C versus Optisol-GS como meio de preservação corneana. Rev Med Hosp Gen Mex 86: 129-134. Available from: http://dx.doi.org/10.24875/HGMX.22000083
Kim DH, Kim J, Jeong HJ, Lee HJ, Kim MK, Wee WR. 2016. Compatibilidade biofísico-funcional da córnea de mini suíno da Universidade Nacional de Seul (SNU) como enxerto xenocorneano para uso em ensaio clínico humano. Xenotransplantation 23: 202-210. Available from: https://doi.org/10.1111/xen.12234
Shi Y, Bikkuzin T, Song Z, Jin X, Jin H, Li X, Zhang H. 2017. Avaliação abrangente da córnea suína descelularizada após transplante clínico. Xenotransplantation 24: 1-7. Available from: https://doi.org/10.1111/xen.12338
Heichel J, Wilhelm F, Kunert KS, Hammer T. 2016. Achados topográficos da córnea suína. Med Hypothesis Discov Innov Ophthalmol 5: 125-131. Available from: https://mehdijournal.com/index.php/mehdiophthalmol/article/view/308
Sanchez I, Martin R, Ussa F, Fernandez-Bueno I. 2011. Os parâmetros do globo ocular suíno. Graefes Arch Clin Exp Ophthalmol 249: 475-482. Available from: https://doi.org/10.1007/s00417-011-1617-9
Chan KY, Cho P, Boost M. 2014. Viabilidade de células epiteliais corneanas em modelo ex vivo de olho suíno. Clin Exp Optom 97: 337-340. Available from: https://doi.org/10.1111/cxo.12128
Hwang, H, Kim M. 2009. Dano endotelial de uma córnea doadora dependendo do método de inserção do doador durante a ceratoplastia endotelial automatizada com retirada de Descemet em olhos suínos. Jpn J Ophthalmol 53: 523-530. Available from: https://doi.org/10.1007/s10384-009-0713-4
Albuquerque L, Freitas LVRP, Pigatto JAT. 2016. Análise do endotélio corneano em olhos de galinhas utilizando microscopia especular de contato. Semina: Ciênc Agrár 36: 4199-4205. Available from: https://doi.org/10.5433/1679-0359.2015v36n6Supl2p4199
Azevedo MG, Méndez NP, Cargnin LS, Rocha RS, Seibel MP, Silva AF, Pigatto JAT. 2023. Microscopia especular das células endoteliais da córnea de bovinos: um estudo ex vivo. Open Vet J 13: 1554-1561. Available from: https://doi.org/10.5455/ovj.2023.v13.i12.5
Bercht BS, Albuquerque L, Araújo ACP, Pigatto JAT. 2015. Microscopia especular para determinação da morfologia e morfometria das células endoteliais da córnea em chinchilas (Chinchilla lanigera) in vivo. Vet Ophthalmol 48: 137-142. Available from: https://doi.org/10.1111/vop.12236
Vargas EVB, Pigatto AM, Rocha RS, Franceschini MEM, Pigatto JAT. 2023. Microscopia especular das diferentes regiões da córnea em olhos suínos enucleados – avaliação ex vivo. Ciênc Anim Bras 24: 1-6. Available from: https://doi.org/10.1590/1809-6891v24e-75138E
Mistò R, Giurgola L, Pateri F, Limongelli A, Ragazzi E, Tothova JD. 2020. Um novo meio de conservação contendo anfotericina B versus Optisol-GS para preservação de córneas humanas doadoras. Br J Ophthalmol 106: 1-6. Available from: https://doi.org/10.1136/bjophthalmol-2020-317136
Abramson, JH. 2011. WINPEPI atualizado: programas de computador para epidemiologistas e seu potencial didático. Epidemiol Perspect Innov 8: 1. Available from: https://doi.org/10.1186/1742-5573-8-1
Andrew SE, Samuelson DA, Lewis PA, Kubilis PS. 1999. Comparação entre Optisol-GS e solução oftálmica de neomicina-polimixina B-gramicidina para armazenamento de córneas em cães. Vet Ophthalmol 2: 155-161. Available from: https://doi.org/10.1046/j.1463-5224.1999.00070.x
Chaurasia S, Vanathi M. 2021. Microscopia especular na prática clínica. Indian J Ophthalmol 69: 517-524. Available from: https://doi.org/10.4103/ijo.IJO_574_20
Sharma N, Shaikh F, Nagpal R, Manumuraleekrishna, Maharana PK, Agarwal T, Sinha R, Satpathy G, Velpandian T, Titiyal JS. 2021. Avaliação de diversos meios de preservação para armazenamento de córneas doadoras. Indian J Ophthalmol 69: 2452-2456. Available from: https://doi.org/10.4103/ijo.IJO_258_21
Gimenes I, Pintor AVB, Sardinha MS, Marañón-Vázquez GA, Gonzalez MS, Presgrave OCF, Maia LC, Alves GG. 2022. Meios de armazenamento a frio versus Optisol-GS na preservação da qualidade corneana para ceratoplastia: uma revisão sistemática. Appl Sci 12: 1-30. Available from: https://doi.org/10.3390/app12147079
Javadi MA, Arkbarzadeh AR, Chamani T, Kanavi MR. 2021. Sinasol versus Optisol-GS para preservação a frio da córnea humana: estudo prospectivo ex vivo e clínico. Cell Tissue Bank 22: 563-574. Available from: https://doi.org/10.1007/s10561-021-09930-y
Guimarães CB, Albuquerque L, Torikachvili M, Vargas EV, Dall-A’gnol CC, Silva TC, Pigatto JAT. 2019. Efeitos do besilato de atracúrio sobre o endotélio corneano de galinhas: estudo in vitro. Pesq Vet Bras 39: 70-74. Available from: https://doi.org/10.1590/1678-5150-PVB-5595
Park S, Fong A, Cho H, Zhang C, Gritz D, Mian G, Herzlich A, Gore P, Morganti A, Chuck R. 2012. Protocolo para coloração vital de células endoteliais da córnea. Cornea 31: 1476-1479. Available from: https://doi.org/10.1097/ico.0b013e31824d0dda
Means TL, Geroski DH, Hadley A, Lynn MJ, Edelhauser HF. 1995. Viabilidade do endotélio corneano humano após armazenamento em Optisol-GS. Arch Ophthalmol 113: 805-809. Available from: https://doi.org/10.1001/archopht.1995.01100060131047
Parekh M, Salvalaio G, Ferrari S, Amoureux MC, Albrecht C, Fortier D, Ponzin D. 2014. Um método quantitativo para avaliar a qualidade do tecido corneano doador utilizado em um estudo comparativo entre dois meios de preservação por hipotermia. Cell Tissue Bank 15: 543-554. Available from: https://doi.org/10.1007/s10561-014-9424-2
Published
How to Cite
Issue
Section
License
Copyright (c) 2025 Brazilian Animal Science/ Ciência Animal Brasileira

This work is licensed under a Creative Commons Attribution 4.0 International License.
Authors who publish with this journal agree to the following terms:
- Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution License that allows others to share the work with an acknowledgement of the work's authorship and initial publication in this journal.
- Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.
- Authors are permitted and encouraged to post their work online (e.g. in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work (See The Effect of Open Access).
Data statement
-
The research data is available on demand, condition justified in the manuscript























