ANÁLISE EXPERIMENTAL DA RESISTÊNCIA À FLEXÃO SIMPLES DE VIGAS DE AÇO TIPO "I" COMPOSTAS DE PERFIS LAMINADOS DOTADAS DE EMENDAS SOLDADAS (doi:10.5216/reec.V11i1.37718)
DOI:
https://doi.org/10.5216/reec.V11i1.37718Abstract
RESUMO: Este artigo apresenta o estudo experimental da capacidade resistente de vigas bi apoiadas em aço constituídas de perfis laminados de seção I do tipo W 250 x 22,3 ASTM A572 grau 50 laminados de abas paralelas com dois eixos de simetria, sendo dotadas de emendas com soldas de penetração total do tipo MIG (Metal Inert Gas). Foram ensaiadas sete vigas com comprimento de 3000 mm, sendo uma viga de referência. Nas seis vigas restantes foram confeccionadas emendas em diferentes posições variando a quantidade de emendas. Além disso, faz-se uma comparação com o comportamento de vigas com emendas parafusadas estudadas por Pereira (2014), no qual utilizou vigas com emendas nas mesmas disposições das utilizadas neste trabalho, mas com parafusos ASTM A325 e diâmetro de 19 mm. Todos os modelos foram submetidos a esforços de flexão simples até à ruptura, no qual foram medidos os deslocamentos verticais, deslocamentos relativos à torção e as deformações específicas do aço. As ligações das vigas resistiram aos ensaios de flexão simples, não sendo constatada nenhuma ruptura nas soldas e nem nos parafusos. A principal contribuição deste trabalho foi mostrar que as vigas com ligações soldadas e parafusadas, com as especificações descritas neste trabalho, podem ser utilizadas como elementos estruturais, pois resistiram bem aos esforços solicitados. ABSTRACT: This paper presents the experimental study of bearing capacity of bi supported by steel beams made of rolled section I of type W 250 x 22.3 ASTM A572 grade 50 profiles rolled parallel tabs with two axes of symmetry, being endowed with amendments with full penetration welds of type MIG (Metal Inert Gas). Seven beams were tested with a length of 3000 mm, with a reference beam. In the remaining six beams amendments were made in different positions varying the amount of amendments. Furthermore, it is a comparison with the behavior of beams with bolt seams studied by Pereira (2014), in which beams used with the same provisions of seams used in this work, but with ASTM A325 and screw diameter of 19 mm. All models were subjected to simple bending stress at break, in which the vertical displacements were measured relative displacements and specific torsional deformations steel. The links of beams resisted the simple bending tests, not being detected no break in welds and even the screws. The main contribution of this work was to show that the beams with welded and bolted connections with the specifications described in this paper can be used as structural elements, as well resisted the efforts required.Downloads
Download data is not yet available.
Downloads
Published
2016-02-01
How to Cite
FREITAS BORGES, R. S.; FERREIRA GOMES, O. ANÁLISE EXPERIMENTAL DA RESISTÊNCIA À FLEXÃO SIMPLES DE VIGAS DE AÇO TIPO "I" COMPOSTAS DE PERFIS LAMINADOS DOTADAS DE EMENDAS SOLDADAS (doi:10.5216/reec.V11i1.37718). REEC - Revista Eletrônica de Engenharia Civil, Goiânia, v. 11, n. 1, 2016. DOI: 10.5216/reec.V11i1.37718. Disponível em: https://revistas.ufg.br/reec/article/view/37718. Acesso em: 20 dec. 2024.
Issue
Section
Estruturas
License
Autores que publicam nesta revista concordam com os seguintes termos: Autores mantém os direitos autorais e concedem à revista o direito de primeira publicação, com o trabalho simultaneamente licenciado sob a Licença Creative Commons Attribution que permite o compartilhamento do trabalho com reconhecimento da autoria e publicação inicial nesta revista.