Análise da eficiência de localizadores de armadura eletromagnéticos: um estudo comparativo

Autores

  • Diego Jesus de Souza University of Ottawa, Ontario, Canada, diegojesusdesouza@gmail.com
  • Marcelo Henrique Farias de Medeiros Universidade Federal do Paraná, Departamento de Construção Civil, Curitiba, Paraná, Brasil, medeiros.ufpr@gmail.com

DOI:

https://doi.org/10.5216/reec.v14i1.45786

Resumo

Na inexistência dos projetos executivos é possível determinar a armadura da estrutura e o seu respectivo cobrimento a partir de aparelhos denominados pacômetros. O presente trabalho tem como objetivo analisar as leituras de equipamentos de dois modelos, o Profometer 5+ e o Wallscanner D-Tect 150, utilizados na detecção das armaduras e cobrimento de um dos pilares do viaduto em Curitiba. A metodologia desenvolvida foi dividida em três etapas, a primeira, para calibração dos equipamentos, realizada em pilares pré-moldados de concreto armado. Na segunda fase, foram executadas leituras em um pilar de um edifício comercial e finalmente, na terceira etapa foram realizadas medições em um pilar com armação desconhecida localizado no viaduto. As leituras realizadas mostraram a eficiência dos equipamentos na localização das armaduras, porém, apresentaram pouca precisão na determinação dos diâmetros das barras. Não foram detectadas armaduras localizadas em camadas mais profundas. Os dois aparelhos permitiram a estimativa do cobrimento das barras detectadas, contudo, a leitura foi bastante afetada em zonas de alta concentração de armadura. Os resultados obtidos, aliados à leveza e facilidade de uso dos equipamentos, permitiram concluir que é recomendável a utilização de pacômetros em inspeções preliminares de pilares de estruturas de concreto armado.

Abstract

In the absence of the executive projects it is possible to determine the armature of the structure and its respective covering from devices called pacemakers. The present work has the objective of analyzing the equipment readings of two models, Profometer 5+ and Wallscanner D-Tect 150, used in the detection of the reinforcement and covering of one of the columns of the bridge in Curitiba. The methodology developed was divided into three stages, the first one, for equipment calibration, performed on precast concrete columns. In the second phase, readings were performed on a column of a commercial building and finally, in the third stage measurements were made on a column with unknown frame located on the viaduct. The readings showed the efficiency of the equipment in the location of the reinforcement, but presented little precision in the determination of the bar diameters. No reinforcement was found located in deeper layers. The two devices allowed the estimation of the covering of the detected bars, however, the reading was very affected in zones of high concentration of reinforcement. The results obtained, combined with the lightness and ease of use of the equipment, allowed us to conclude that the use of pacometers in preliminary inspections of pillars of reinforced concrete structures is recommended.

Downloads

Não há dados estatísticos.

Biografia do Autor

Diego Jesus de Souza, University of Ottawa, Ontario, Canada, diegojesusdesouza@gmail.com

Marcelo Henrique Farias de Medeiros, Universidade Federal do Paraná, Departamento de Construção Civil, Curitiba, Paraná, Brasil, medeiros.ufpr@gmail.com

Downloads

Publicado

2017-09-19

Como Citar

JESUS DE SOUZA, D. .; HENRIQUE FARIAS DE MEDEIROS, M. . Análise da eficiência de localizadores de armadura eletromagnéticos: um estudo comparativo . REEC - Revista Eletrônica de Engenharia Civil, Goiânia, v. 14, n. 1, 2017. DOI: 10.5216/reec.v14i1.45786. Disponível em: https://revistas.ufg.br/reec/article/view/45786. Acesso em: 28 mar. 2024.

Edição

Seção

Notas Técnicas